| Traction, rope pressure, rope safety |
| Traction empty,on top, accelerating |
| 1,5267 <= 1,7866 |
| Traction 150% nominal load, below, not moving |
| 1,4755 <= 1,7866 |
| Rope pressure k < permissible rope pressure |
| 6,45 < 9,00 N/mm² |
| Conditions according to EN81: |
| Load 125% | 1,3804 <= 1,8119 (2) |
| Emergency stop | 1,4727 <= 1,5289 (2) |
| with deceleration [m/s˛] 0,500 |
| Blocked car | 05,064 > 3,2830 (4) |
| Real safety factor > Minimum safety factor for ropes |
| 24,36 > 12 |
| Rope safety factor according to EN81: (0), Basis 0 |
| Pulleys >= 400 mm, pulleys NPR = 0 NPS = 2 |
| Rope safety nue = 24,4 > 16,4 (minSF) |
| Rope certification EN81 |
| Traction conditions are fulfilled. |
| Rope safety conditions are fulfilled. |
|
| ZAlift - 20210816 - Machine dimensioning ZAL-174936 |
| Mechanical drive data |
| Machine manufactured by Ziehl-Abegg |
| Machine type | SM 200.45E Gearless synchronous |
| Machine version ZAtop * |
| Traction sheave | mm 400 /95/17,0/5x10/HU90 |
| Permissible load output torque | Nm 654 (max. 799) |
| Real statical axle load | kg 2378 (max. 3600) |
| - |
| - |
| Brake data |
| brake Mayr ROBA-twinstop RTW800, 2x800 Nm, EU-BD 1112 |
| Dual circuit disc brake. DC supply necessary |
| (540 Nm, 0,51 m/s², 5 m, 41787 J, 264 W) |
| 207 V brake. with hand release. microswitch |
| - |
| Machine load data in the installation |
| Typical motor operating power | kW 8,9 |
| Typ. operating current 33,2 A, Start. Current 67,6 A at acceleration 0,90 m/s² |
| Start. Current | 59,6 A at acceleration 0,7 m/s² |
| Average power losses | 1,93 kW = 6936,43 kJ/h |
| Output speed | rpm 191 |
| Load torque | Nm 654,1(eff. 447,3) |
| Inertia of installation | kgm² 51,08 |
| 240 Starts per hour , 70 % required duty cycle at elevator operation |
| Max. static load pulleys 20631 N, pulley speed 2,00 m/s |
| Selected frequency inverter |
| Inverter ZAdynpro050, Rated inverter current 50 A |
| mains current 24,3 A, 400 V, 16,0 kW, Max. 1,06 m/s², F_amax 1,83 (1200 Nm) |
| Radio interference filter. integrated ; Line reactor. separate ND050 |
| Braking resistance BR50-3 |
| Brake control module ohne |
| Stopping distance (without traction influence) | 0,297 m, empty up |
| Max. stopping distance (traction depending) | 0,471 m, empty up |
| Max. stopping distance (traction depending) | 0,358 m, full down |
| Max. stopping distance (inverter off, empty) | 0,168 m, empty up |
| Max. test stopping distance(v= 0,150m/s) | 0,092 m, empty up |
| Max. test stopping distance(v= 0,150m/s) | 0,090 m, full down |
| Max. test stopping distance(a= 2,000 m/s²) | 0,250 m, empty up |
| Max. test stopping distance(a= 2,000 m/s²) | 0,250 m, full down |